5.7 System Testing
This section describes operation of fire drills, zone testing, and the 24-hour automatic test.
5.7.1 Fire Drills
Fire drills can be run from either the on-board touchpad or the Model SK-5235 Remote Annunciator. To initiate
a fire drill, press 20 ENTER + Code. The system will sound an alarm and report a fire test. To end the fire drill,
press
RESET + Code.
5.7.2 Walk Test
The walk test is designed to be used for on-site testing only.
To enter walk test mode, press 22 ENTER
+ Installer Code.
Select the following test parameters:
The LCD will indicate that you are in walk test mode. When a zone is tripped, the SK-5208 will activate the bell
outputs for approximately six second and will cycle smoke power off and on for the programmed time interval.
When smoke power is restored, there is a two-second power up delay before the zone will respond to additional
test inputs.
The system will time out and resume normal operation in 30 minutes if no keys are pressed or no zones are
tripped during the walk test.
To exit walk test mode, press
RESET.
5.7.3 Automatic Self Test
The Model SK-5208 lets you select the time of day and the interval that the automatic that the test signal will be
sent to the central station. See Sections 4.2.10 and 4.3 for additional information on automatic test time.
5.7.4 Watchdog Circuit
During normal operation, the control microprocessor of the SK-5208 is constantly running programs to check
inputs and carry out other routine functions. If the program should ever stop running, the watchdog circuit will
automatically detect this and attempt to resume normal operation by resetting the microprocessors. Each time the
watchdog circuit initiates a reset signal, it will also sound the audible trouble signal for approximately four
seconds.
5.8 Communicating with a Programming Computer
An installer at the panel site can initiate communications between the panel and a computer running the Silent
Knight Software Suite SKSS. In order for this communication to function properly both the computer (running
the software) and the control panel must have matching computer account numbers and computer access codes.
Before you program in this location you should know how your control panel will communicate with the
downloading computer, either through direct connect (RS232) or via the phone lines (Internal Modem).
Test Feature Enable or Disable Comments
Use Verify: Yes or No If Yes is selected then this option will be enabled during
walk test. If No is selected this option will be disabled
during walk test.
Mapped Rlys: Yes or No
Mapped NACs: Yes or No