18
BYPASS#2:YES
If this option is selected this code will be able to bypass (disable) intrusion zones.
ARM#2:YES
This option enables the code to be used to arm (close) the system.
DISARM#2:YES
This option enables the code to be used to disarm (open) the system.
PROGRAM#2:YES
This option enables the code to be used to program the secret codes for user codes 2-255 and
the user-programmable options (Time Windows, Holidays, Access options) and daylight sav-
ings time adjust dates.
CODE2#2:NO
When this option is selected, the code becomes a restricted code, for use by guests,
baby-sitters, and other temporary system users.
This means that when the CODE2 key is pressed, the code can disarm the system once. Nor-
mally CODE2 restricted codes can never disarm the system.
HIGH SEC#2:NO
When this option is selected, the code becomes a high security code, which will require the
high security code for door access. The high security code (Code 255) is entered on the touch-
pad after the primary code.
CARD ONLY#2:NO
The Card Only option allows a person to gain access to a door only by a card, not by a touch-
pad.
WIN GRP#2:32
Select the time window group (programmed in Window Groups, Menu 9) during which each
access code can be used.
To make it possible to use a particular code all the time, select “always” (3 2).
To make it impossible to use a particular code at any time (for example, because the
card has been lost) select “never” (3 3).
Example:
Suppose you have programmed Time Window #1 for 8:00 AM to 5:00 PM, Monday
through Friday, and you have programmed Time Window #2 for 10:00 AM to 5 PM on
Saturdays (Time Windows, Menu 0). Then, suppose you have assigned Windows #1 and
#2 to Window Group #4 (Window Groups, Menu 9).
If you want the code to be able to gain access and/or use a touchpad during the times from
8:00 AM to 5:00 PM on weekdays, and from 10:00 AM to 5 PM on Saturdays, then select
Error! for the WIN GRP option. Any group can be assigned to any code and to more than
one code. A code can be assigned to only one window group.
Page view 25