Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
22
EXIT BEEPS:NO
This option causes an audible warning tone to be sounded during the exit delay.
SIL NGHT TRB:NO (Silent Night Trouble)
When this option is selected, audible trouble tones will not be sounded while the panel is
armed.
KEY BEEP SPK:NO
If the installation includes a touchpad without a PZT beeper, you can use this option to send
the “beeps” from the touchpad to the internal speakers—however, they will sound at all inter-
nal speakers.
E/E BEEP PZT:YES
Select this option if you wish to have the entry/exit tones sounded on the PZT beeper. (These
tones are always audible on the internal speakers.)
SWINGER BYPS:YES
When this option is selected, the system automatically bypasses any zone that generates four
alarms within a specified time period (programmed in Timers, Menu 11).
DELAYED BYPASS:YES
When this option is selected, the system will not report bypasses to the central station until the
panel is armed.
AUT UNBYPASS:NO
This option will automatically unbypass the bypassed zones when the panel is disarmed, to
allow trouble conditions to be reported.
NOTE Since Force Arming may automatically cause zones to be bypassed, the Auto Unbypass option
should be selected if the Force Arm option is enabled.
BYPASS CODE:NO
Selecting this option makes it impossible to bypass or unbypass a zone without first entering an
access code, even if the panel is disarmed.
ACCESS WINDW:NO
If this option is selected all access codes are restricted to the time windows that have been
assigned to them (Access, Menu 1). Selecting NO disables all time restrictions.
If you will be using access windows, see Section 8.1 of this manual. The access windows
restrict all functions that require an access code to certain times and days.
REP DO/DF:NO (Report Door Open/Door Forced)
Selecting this option causes the system to send a report every time the door sensor is violated
without using door access. It will report if the door is forced open or left open.
REP ALL O/C:NO
This option causes the system to report all openings and closings.