Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
24
DURESS:NO
This option allows the use of the Duress feature of the 4724. The duress trigger is a two-digit
code that the user can enter to notify the central station that an intruder has forced the user to
enter an access code.
DURESS TRIG:99
If the Duress option has been selected, you must enter a one- or two-digit code that will acti-
vate a duress alarm.
NOTE The digits entered cannot be the same as the beginning digits of any access code.
HIDE CODES:NO
If this option is enabled, system users cannot see all codes when programming new codes.
Codes with programming ability can change secret codes, but they will see “****” in place of
the digits of the code. This feature applies only to Code 2 through Code 255. When the Code 0
and Code 1 are used to program codes, the digits of the code(s) will display. (This option is
new with the 4724-2, Revision J2 [or later].)
RING B CLOSE:NO (Ring Back at Closing)
When this option is selected, there will be a short bell test after kiss-off when a Closing Report
is sent.
BELL TST ARM:NO
Selecting this option causes a two-second bell test every time the system is armed.
AUX CODE:NO
When this option is selected, it is necessary to use an access code to toggle auxiliary control
(Model 4150) relays or X-10 Modules.
AUTO CLOSE:NO
Selecting this option causes the system to arm itself automatically, if the panel is not armed at
the end of any time window in the auto close window group (CL WIN GRP).
NOTE A. UL installations must NOT select the above option.
B. If you are using auto open/close in a multi-area system, see Section 5.1.3 of this manual for
more information.