SILENT KNIGHT 4720 Installation Manual Page 45

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 44
Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
37
NOTE Characters preceded by ¥ are “display macros” (see Section 7.5 of this manual).
¥D causes the actual date to be displayed as part of the message.
¥T causes the time to be displayed.
When using the 5540 Downloading Software, “\” replaces the “¥” character.
8.12 Timers (Menu 11)
SHUTDWN:90s
Decide the number of seconds that you want the audible alarms to be active. Then divide this
number by 10 and enter the result (1-255).
EXIT:30s
Enter (in seconds) the length of the exit delay (1-255).
ENTRY1:30s
Enter (in seconds) the length of the entry delay for zones controlled by Entry Delay #1 (1-255).
ENTRY2:60s
Enter (in seconds) the length of the entry delay for zones controlled by Entry Delay #2 (1-255).
SWINGER BYPS:4h
Enter (in hours) the length of the swinger window (1-24). If the SWINGER BYPS option has
been selected (System, Menu 4), a swinger bypass (shunt) will occur on the fifth trip when a
zone has caused four alarms within this time period.
RF SUPRV:24h
Enter (in hours) the supervision interval (2-24).
Example:
If you enter 3 the system will check for supervisory transmissions from the RF transmit-
ters every three hours.
DOOR STRK:6 .8s
In this step, you will program the length of time that the doorstrike stays activated (0.8-12 sec-
onds). The display will always show “.8” to indicate that the programmed length of time is 0.8
seconds times the number you select. 4660 series touchpads use one second timers.
NOTE This time period is the maximum length of time the doorstrike will remain activated, allowing
someone to open the door. If a door contact is connected to the touchpad, the doorstrike will
turn off one second after someone opens the door. If no door contact is connected to the touch-
pad, the doorstrike will remain activated for the programmed length of time, regardless of
whether the door has been opened.
DOOR OPEN:60s
Enter (in seconds) the maximum time that the door can remain open before the system will
send a Door Left Open Report (1-255 seconds).
REP DELAY:15s
Enter (in seconds) the amount of delay that you wish to have between the time that an alarm
condition is sensed and when the system will actually report the alarm (1-255 seconds).
Delayed reporting is selectable by zone in Zone Types (Menu 6).