SILENT KNIGHT 4720 Installation Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 82
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
21
ZONE EXP2:NO
If two zone expanders are to be used with the system, both ZONE EXP1 and ZONE EXP2
must be selected.
INTERCOM:NO
Select this option if you are using the Model 4140 Intercom/Speakerphone.
AUX CONTROL:NO
Select this option if you are using the Model 4150 Auxiliary Control Module.
SPLIT ARM:NO
This option must be selected in order for the Area Control features to operate.
NOTE With Revision H (or later) of the 4724, this option must also be selected if the system uses auto
open/close areas. See Section 5.1 of this manual if you need more information.
ARM MENU (Revision H )
This causes the Interactive Arm Menu, which is normally used in split arm systems, to be
active in all systems when a code is entered.
INST INTR:NO
When this option is selected, all delayed zones become instant zones whenever any intrusion
alarm occurs.
FORCE ARM:NO
This option causes any zones that are not ready to be bypassed (shunted) when the system is
armed. Upon arming the 4724 will generate a “CF” (Forced Closing) Report.
NOTE Since force arming may automatically cause zones to be bypassed, the Auto Bypass option
should be selected if the Force Arm option is enabled.
INTR INTRU:NO
When this option is selected all interior zones will automatically be enabled when there is an
intrusion alarm.
INTR FLWRS:NO (Interior Followers)
Selecting this option causes interior zone annunciations and reports to be delayed when an
entry zone is violated.
INTR LOCK:NO
This option disables the INT and DLY keys whenever the system is armed (after the exit
delay). This prevents anyone from disabling the interior zones while the system is armed.
AUT INTR OFF:NO
When selected, this option will automatically disable the interior zones when the system is dis-
armed.
AUT INTR ON:NO
When this option is selected, the interior zones will automatically be enabled when the panel is
armed. The system will not arm, unless the interior zones are ready. If the interior zones are
subsequently turned off by the user, a Forced Close Report will be generated.