Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
29
RESD CODE#2:0223
Follow this step only if you are using an obsolete Silent Knight RF Zone Expander. If Zone
Expander #2 is an RF zone expander, enter its residence code.
NOTE Skip this step if you are NOT using an obsolete Silent Knight RF zone expander.
ZONE:#1
Select the zone you want to reprogram.
DAY TRBL#1:NO
If this option is selected, the zone will be supervised only while the zone is disarmed. Day trou-
ble loop response is always .062 seconds. Day troubles will not restore, until silenced from a
touchpad. Typical day trouble zones are window foils or emergency exits. If you select DAY
TRBL for a zone, you must also select N.C. for that zone.
24HR TRBL#1:NO
Select this option for any zone that will be supervised 24 hours a day, such as a fire zones (all
supervised zones require a 15 K ohm EOL). 24 hour trouble loop response is always 10 sec-
onds. A 24 hour trouble will restore as soon as the loop is restored. If you select DAY TRBL
for a zone, you must also select N.C. for that zone.
NOTE Do NOT pick both 24 HR TRBL and DAY TRBL
N.C.#1:NO
Select this option if the zone will be using normally closed contacts.
NOTE All N.C. zones require a 15 K ohm EOL.
N.O.#1:YES
Select this option when the zone will be using normally open contacts.
NO EOL:NO
Use this option if necessary per instructions in the 4115 Serial Zone Expander Installation
Manual (P/N 150648). Also select this option for N.O. or N.C. 4126 (or 4125) zones not using
an end-of-line (EOL) resistor.
SPEED#1:06s
This option determines the speed at which the zone will respond to an alarm or trouble condi-
tion. Select the number shown next to the desired zone response speed in Table 6. Select also
for N.O. or N.C. 4126 (or 4125) zones not using an end-of-line resistor.
Table 6: Loop Response Times
Selection Loop Response Time
0 0.01 second
1 0.06 second
2 1.00 second
3 10.0 seconds