Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
9
4.2.4 Display Events
To display the event memory, press 1 MEM. The events will be displayed starting with the
oldest event and continuing to the newest event. The event is displayed along with the date and
time it occurred.
After pressing 1 MEM, you must enter a start date to begin the event display. Press the digits
of the month, day, and year, then press TEST. All events on or after this date will be shown.
To show all the events in memory, press CLR TEST.
NOTE If you are using software revisions A-G, you cannot enter the year when viewing events.
4.2.5 Clear Events
1. To clear the event memory, press 1 0 TEST and enter a code with Program mode access.
2. Press 1 to erase the memory, press 0 to quit, or press the TEST key to continue.
4.2.6 Zone Display
Press 1 STAT to display all zone locations assigned to the same areas as the touchpad.
4.2.7 Touchpad Display
Press 2 STAT to view the location of the touchpad you are currently using.
4.2.8 Software Revision
Press 4 STAT to view the 4724 software revision date.
Section 5: Area Control
An area is a part of a building that is being treated as a subsection of the total system. The
Model 4724 allows an installation to be divided into up to eight areas. There are two possible
levels of system operation using areas: split and simple system arming.
5.1 Levels of Area Control
5.1.1 Simple System
Area programming is used to divide system door access into separate areas. Codes and touch-
pads for each area are programmed to determine who will to gain access at the touchpad. Arm-
ing and other functions operate at all stations and apply to the entire system, not to individual
areas.
5.1.2 Split Arming
Split arming offers a high degree of independent operation for each area. Each area can be
independently armed and disarmed. Each area has its own entry and exit timer. Entry or exit
zones assigned to that area will be disabled during the entry or exit time for the area. The pro-
grammed entry and exit times are shared by all areas.
Interior and Instant operation are also controlled separately for each area. Each area has its
own interior zones and interior active status. Each area has its own instant status that disables
the entry and exit timers for that area.
CODE2 operation applies separately for each area. When the Code2 feature is activated,
Code2 restricted access codes may disarm the area once. Normally Code2 restricted codes can
never disarm the system.
Each area can be armed and disarmed using only touchpads and codes that have been assigned
to that area.