Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
20
DOOR DISARM:NO
This option causes the areas assigned to a particular access code to disarm automatically when
door access is granted to that access code.
NOTE This option is effective only if the code has been programmed with the capability to disarm
(Access, Menu 1).
REP/PR EXIT:NO
This option causes all door exit events to be printed and reported to the central station. Exit
requests are printed and reported as DOOR ACCESS ID 0.
PR DOOR:NO
This option causes all door access events to be printed.
NOTE If you also select REP DOOR (see Section 5.7 of this manual), door access events will be
printed and reported to the central station.
BELL TST PU:NO (Bell Test at Power-Up)
This option causes the system to sound a two-second bell test whenever the system is reset.
DIALER:YES
The dialer must always be selected for normal operation. It can be disabled for troubleshooting
or while training system users. When the dialer is disabled there is no battery or AC detection.
PRINTER:NO
Select this option if you are using a Model 5255 On-Site Printer or Model 5260 Printer Inter-
face.
ZONE EXP1:NO
If at least one zone expander is to be used with the system, this option must be selected.
Table 4: Default Mode Selection
Selection Default Mode
0 The system will default to the Disarmed mode and will NOT gener-
ate an Open Report to the central station.
1 The system will default to the Disarmed mode and will generate an
Open Report.
2 The system will default to the Armed mode and will automatically
bypass (shunt) any zones that are not ready to be armed. The unit will
also generate a Close Report.
3 The unit will default to the Armed mode. If any zones are not ready
to be armed. They will go into the Alarm condition and the appropri-
ate report will be sent to the central station. If all of the zones are
ready, only a Close Report will be generated.