Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
54
9.5 Programming the I/O Statements
9.5.1 What the I/O Statements Do
NOTE It is easier to program I/O statements using the Model 5440 Downloading Software. Because it may some-
times be useful to program have program them with the built-in programmer, the procedure is explained
in Section 8.17 of this manual.
The 4724's programmable I/O capability allows you to configure auxiliary output devices to act as indica-
tors of internal status conditions or to respond to the internal conditions in some way. Figure 5 shows the
I/O programming software in relation to the programmable output devices.
Figure 5: Auxiliary Devices
Outputs are generated on three types of devices:
1. Model 4720 panel Terminals 15, 16 and 18. Terminals 15 and 16 are open collector outputs that
sink current when activated (negative voltage, -12 VDC, 50 mA maximum). Terminal 18 functions as
a current source when activated (positive voltage; +12 VDC, 20 mA maximum). Figure 6 shows how
each of these terminals would be connected to an output device.
NOTE The default I/O program sets Terminal 15 as a common fire alarm output and Terminal 16 as a common
intrusion alarm output.
16 OUTPUTS,
4 RELAYS EACH
8457G16A.DSF
LAMPS, APPLIANCES, ETC
MODEL 4180
#1
4724
USER PROGRAM
ZONE STATUS ALARMS,
TIME WINDOWS,
ENTRY/EXIT
AREA STATUS,
KEY COMMAND,
AUX. CONTROL,
DIALER STATUS,
ETC.
MODEL 4180
#2
.
UP TO 32 X-10 MODULES.
4181 (PL513)
POWERLINE
INTERFACE
LONG RANGE RF,
STATUS DISPLAY
DEVICES, ETC.
HOUSE
WIRING