Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
28
TOTAL ATTM:10
Enter the overall number of attempts (1-15) that the communicator will try to dial out using all
phone numbers. Select 0 for both FAIL ATTM and TOTAL ATTM for a local-only system.
# RINGS:10
This option is used in conjunction with the Downloading feature. You would program the
number of times (1-15) that your phone will ring before the communicator will dial out or
answer for downloading information. If you do not wish to use this feature, enter 0. If you also
selected ANSWER Sand REP. ALL O/C, the armed panel will answer after fewer rings, four
fewer than the programmed number (see note below).
NOTE The panel will not answer until it detects at least two rings.
LOW AC:4h
For this option, program the number of hours (1-15) that the AC power must be off before a
Low-AC Report is generated.
DTMF L1:NO
If this option is selected, Line 1 will use Touch-Tone
®
dialing. If you do not select this option,
the phone line will use rotary type dialing only.
NOTE If you have selected DTMF L1, the dialer will alternate between Touch-Tone
®
and rotary dial-
ing on subsequent attempts.
DTMF L2:NO
If this option is selected, Line 2 will use Touch-Tone
®
dialing.
DTMF ONLY:NO
If this option is selected, Touch-Tone
®
dialing will be used any time the system is dialing out.
8.7 Zone Options (Menu 6)
INTERN ZONES:16
Enter the number of internal zones used (internal zones are those that are built into the Model
4720 panel). This will let the system know where to start the expansion zones.
EXP ZONES#1:0
Enter the number of zones used on Expander #1.
RESD CODE#1:0123
Follow this step only if you are using an obsolete Silent Knight RF Zone Expander. Select the
residence code to be used with RF Zone Expander #1. This code must be the same as the resi-
dence code programmed into the transmitters. (For more information, see the section on expan-
sion zones in the 4720 Installation Manual (P/N 150476).)
NOTE Skip this step if you are NOT using an obsolete Silent Knight RF zone expander.
EXP ZONES#2:0
Enter the number of zones used on Zone Expander #2.