Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
26
CL WIN GRP:32
This option makes it possible to have more than one closing period in a day using Revision A-
G software. See Menu 14 for Revision H information.
NOTE Revision A-G: For this option, select the window group during which the system can be armed.
At the end of this time period, the system will automatically arm (close), if it is not already
armed by a user and if Auto Close is enabled (see Sections 5.1 and 11.1 of this manual). If arm
the delay is programmed to be greater than 0, the arm delay begins at the end of the close win-
dow group.
Revision H: The option is retained here for programmable I/O compatibility. This option is not
used on Revision H software. It is replaced by a similar option for each area in Menu 14. OP
WIN GRP controls bit OPGRP in the programmable I/O. CL WIN GRP controls CLGRP.
AREAS:-----
Choose areas that can auto open/close.
NOTE In Revision H, the above item is moved to Menu 14, Area options.
X-10 HC 1:A
This option allows you to choose the house codes for the first 16 of the 32 allowable X-10
Modules. There is a choice of 16 letters, from which one house code can be selected for this
option. Enter the number next to the desired letters in Table 5.
The house code you select should be different from those of any other X-10 Modules that are
in the building that you do not wish to be connected to the 4000 system.
X-10 HC 2:B
Select the second house code. This house code will apply to the last 16 of the 32 allowable X-
10 Modules.
NO PULS BELL:NO
Select YES for steady fire bell output. (Used for strobes.)
HOLDUP RSTR:NO
Select YES to have holdup zones send restores to the central monitoring station.
SEP RESTORES:NO
Select YES to separate trouble and alarm restores. Select NO to send any restore to the central
monitoring station
FIRE PRIORITY:NO
Select YES to have fire alarms sent first to the central monitoring station.
Table 5: House Codes
Selection House Code Selection House Code
0
1
2
3
4
5
6
7
A
B
C
D
E
F
G
H
8
9
10
11
12
13
14
15
I
J
K
L
M
N
O
P