Regency
®
Model 4724 Control Expander Installation Manual (P/N 150596-02, Rev. A) Revised 8/98
58
RLY[2].7
Output on 4180 Module 1, Connector P3, Pin 1
TER15
Active low output sink on Terminal 15 of the 4720 panel (50 mA)
TER16
Active low output sink on Terminal 15 of the 4720 panel (50 mA)
TER18
High output source on Terminal 18 of the 4720 panel (20 mA)-
supplies 12 VDC when turned on
X10[1]
Outputs to X-10 Modules 1-8 of House Code 1
X10[1].0
Outputs to X-10 Modules 1 of House Code 1
X10[1].1
Outputs to X-10 Modules 2 of House Code 1
X10[2]
Outputs to X-10 Modules 9-16 of House Code 1
X10[3]
Outputs to X-10 Modules 1-8 of House Code 2
X10[4]
Outputs to X-10 Modules 9-16 of House Code 2
NOTE On connectors P2 and P3 of the 4180, the designation “.0” refers to Pin 8 and the
designation “.7” refers to Pin 1.
Table 20: Programmable I/O Status Labels (Read-Only)
1
Label
2
Data Type Function
AARMED[8] BIT Area[n] armed
ACCAREA[8] BIT Window group status
ACHIME[8] BIT Area[n] in Chime mode
ACODE2[8] BIT Area[n] in Code2 mode
AENTRY[8] BIT Area[n] in entry delay
AEXIT[8] BIT Area[n] in exit delay
AINST[8] BIT Area[n] instant mode
ALMAREA BITS Areas in alarm
ALMTYP NUMBER Current alarm type
AREADY BIT Area[n] ready
ATROUBLE[8] BIT Area[n] zone trouble
AUDALM BIT Any alarm not silent
AUDAREA BITS Areas using audio
AUXALM BIT Auxiliary alarm type
AUXRLY BITS Auxiliary control relay status
AZONES[18] BITS Zones that are armed
Table 19: Output Designations